Bathroom sanitary ware is one of the most frequently used household products in our daily life. Its installation affects the later use. Improper installation will not only cause sanitary hidden dangers, but also bring many economic hidden dangers. So what aspects should be paid attention to when installing sanitary ware? Well, come and learn with us.
Process flow of the toilet
Check the water outlet pipe on the ground → align the pipe mouth → lay it flat and straighten → draw the mark → punch the hole → apply putty → put on the rubber pad → screw on the nut, → draw the mark on the two side holes on the back of the water tank, → punch the hole →Insert the bolts→Twist firmly→Hang the back water tank flat and align it→Tighten the nut→Install the water elbow of the back water tank→Install the splayed door→Bend the fork of the mother lamp→Insert the floating door and the splayed door→Tighten the nut.
Process flow of washbasin
Insert the expansion bolt → twist it firmly → hang the basin pipe rack → put the washbasin on the rack for leveling → water connection: wash basin → straighten → water supply connection.
Process flow of shower
Use a test tube to level the cold and hot water nozzles → measure the nipple size → install it on the nozzle → apply lead oil to the copper water inlet of the shower, wrap it around → tighten the nut → fix it on the wall → install the upper copper pipe on the tee → Wood screws are fixed to the wall.
Process flow of bidet
The mixing switch, the door cover and nut of the hot and cold water door are leveled, → the water door is installed → the nozzle core door is installed → the outlet nut of the hot and cold water door is tightened → the nut on the mixing switch is tightened → the three water door covers are installed → the magnetic basin is installed
Wash basin installation and construction essentials:
(1) Wash basin products should be flat and free of cracks. The drain plug should have an overflow hole with a diameter of not less than 8mm.
(2) When the drain plug and the washing basin are connected, the overflow hole of the drain plug should be aligned with the overflow hole of the washing basin as much as possible to ensure that the overflow part is unimpeded. After the inlay, the upper end of the drain plug should be lower than the bottom of the washing basin.
(3) The bracket fixing bolts can be galvanized split bolts or galvanized metal expansion bolts not less than 6mm (if the wall is porous bricks, expansion bolts are strictly prohibited).
(4) After the washing basin is connected to the drain pipe, it should be firm and dense, and easy to disassemble, and the connection should not be open. Silicone paste caulking should be applied to the contact between the sink and the wall.
Installation points of sanitary ware
1. Do not damage the waterproof layer. If the waterproof layer has been damaged or there is no waterproof layer, it must be waterproofed first and undergo a 12-hour water leakage test.
2. The sanitary ware is firmly fixed and the pipe joints are tight.
3. Pay attention to the protection of finished products and prevent bumps on sanitary ware.