If the floor heating is laid in the home, the ground will be very warm, and the heat will radiate the corners and corners of the home, it will be very hot. The laying of the heating pipeline is a circle, so that the heat will be balanced, so if the heating is hot and cold, it must be caused by the problem of the heating system. So what’s the problem in general?

One, the floor heating some hot and some cool what is the matter
1. The pipe is blocked
Floor heating pipes need to be cleaned every other year. If left uncleaned for a long time, dirt from the floor will grow in the pipes, clogging them and preventing heating from circulating.

2. Too little stress
If the water pressure in the pipe is too low, then the heat will not reach the end of the pipe and will not be fully heated. At this time, the booster pump should be installed on the heating pipe to restore it to normal.

3. It contains gas
The heating tubes under the floor contain gas, which prevents the heating from circulating and causes one part to be hot and the other to be cold. At this point, close the hot water valve of the heating pipe under the floor, and open the exhaust valve above the pipe until the outflow of water is in a column. This means that all gas in the pipe has been used up.

Two, the heating heat is not uniform how to do
1. Small heat dissipation area
There are obstacles on the ground that affect the heat dissipation effect, such as the use of large carpets. It is recommended to tuck it away to reduce floor coverage and to give off more heat.

2. The laying interval of the floor heating pipe is too large
If the spacing between floor heating pipes is too large, the heat load is too low. Even when the hot water tops out at 60 degrees, the room may not be warm enough. It is recommended to find a professional HVAC company to redesign and install.

3. Not cleaned for a long time
When floor heating is used, the pipes will scale up. The average annual scaling is 1mm, which may result in a 6°C drop in water temperature. It is recommended to find a professional cleaning company for cleaning. If the coil is blocked, you can only break the ground, change the interface, or reinstall it.

4. Uneven circulation
Locate the water distributor and adjust the valve on it so that the heating in your house is the same as that in other houses.

5. The filter is blocked
If the main bar is not hot, the filter is blocked. Turn on the filter, clean the filter, and install.

Three, how long can the floor warm up after opening
If the floor heating system is turned on normally, it will take 3-4 hours to reach the set temperature. Even if the room is relatively damp, it only takes half a day to reach the set temperature. The floor heating is used for about four months a year, and the floor heating has a water distributor in different rooms to control the valves in each area. The temperature in this area can be adjusted on each water supply valve.

When using floor heating for the first time, the correct operation must be followed. First, you need to pour water into the floor heating. Allow water to enter the floor supply pipe after the valves for the floor supply pipe and return pipe. After one week of operation, the water supply temperature will increase by 5-10°C every week. Normal operation will not be possible until the water supply temperature reaches 60-65°C.