HOMENews

How to clean and maintain the ground source heat pump air conditioner?

How to clean and maintain the ground source heat pump air conditioner?

2023-02-17 11:02:02

Condenser maintenance

The maintenance of the condenser can be divided into mechanical cleaning maintenance and chemical cleaning maintenance. The cleaning and maintenance of the condenser is very important. The condenser of the water-cooled unit uses a shell-and-tube water-cooled condenser, so the quality of the cooling water should be kept good, and the cooling water should be chemically treated regularly. , pipeline cleaning machine or chemical cleaning agent to ensure that there is no fouling in the heat transfer tube.

The way to clean the condenser should be determined according to the heat exchange tube type of the condenser. If chemical cleaning is used, it must be uniform. When rinsing with clean water, it must be clean and thorough without residue.

Maintenance of the compressor

In the daily use process, pay attention to check the connection reliability of the inlet and outlet valves of the compressor, and whether there is any leakage; when measuring the running current, the cable should be located in the center of the measurement loop. Judging by the sound of the compressor running to see if there is any abnormality. If the unit has not been used for a long time, you should start the electric heating of the crankcase of the unit first to heat the oil chamber of the unit to evaporate the Freon in the oil of the unit and improve the accuracy of the measurement resistance.

Maintenance of economizers

When maintaining the saving device, pay attention to check and fasten the wiring terminals on the electrical circuit, check the burning conditions of the contactor contacts and the solenoid valves, such as the four-way reversing valve solenoid valve, the unit loading and unloading solenoid valve, and the liquid spray solenoid valve. Whether the valve, electric heating and other actions are normal, check the setting parameters to ensure that the thermal protection is well secured, the wiring is intact, the flow switch is refueled, and the opening and closing actions are normal.

Maintenance of the evaporator

When maintaining the evaporator, special attention should be paid to avoiding damage to the evaporator caused by freezing of water when it is not in use in winter, check the quality of frozen water and the scaling of the evaporator, and do a good job of draining and changing water. The sewage valve at the bottom of the evaporator should be opened Discharge the impurity sludge, and remove the sewage ball valve if necessary to increase the sewage outlet. According to the water color, suspended solids, rust, etc., it is recommended that users manually clean or use chemical cleaning. After draining, refill with clean water, run for 30 minutes and check the water quality again, and work again if necessary.