Liquefied gas can not fire, need to clean the stove, dredge the pipeline, replace the battery, high voltage line, pressure reducing valve, so that the normal use of liquefied gas, if the ignition needle spark, liquefied gas supply is normal, should adjust the distance between the ignition needle and the fire cover, so that it is kept at about five centimeters.

1. Clean the stove
Liquefied gas can not fire, may be the ignition needle is dirty and blocked by kitchen oil, need to turn off the liquefied gas, clean up the stove, the ignition needle and the dirt on the stove clean up, and then open the liquefied gas again, can be restored to use.
2, dredge the pipeline
The gas supply pipeline of liquefied gas is blocked, and there will be no fire. At this time, the valve of liquefied gas should be closed, and the pipeline should be removed for cleaning, so that it can be dredged, or only a new pipeline can be replaced for installation.
3. Replace the battery
The ignition needle of the liquefied gas is powered by the battery. If the battery is exhausted, the liquefied gas will not catch fire. You can replace the new battery and then turn on the liquefied gas again.
4. Correct the position
The distance between the ignition needle of liquefied gas and the fire cover is greater than six centimeters, which will lead to the ignition needle cremation cannot contact the liquefied gas, and the ignition needle will not catch fire naturally. At this time, the ignition needle should be moved to the direction of the fire cover, so that the distance between the two is between four and six centimeters.
5. Replace the high voltage cable
The ignition switch of liquefied gas is connected with a high voltage wire. If the high voltage wire is aging, it will make the liquefied gas not fire. At this time, the high voltage wire should be replaced, and a high voltage protection device should be installed outside the high voltage wire to extend the use time of the high voltage wire.
6. Replace the reducing valve
In the process of using liquefied gas, for the sake of safety, it will set the overpressure protection function. If the pressure of liquefied gas is too large, the protection device will start, resulting in the ignition of liquefied gas. At this time, it is necessary to restore the protection device to its original state and change a reducing valve to control the pressure of liquefied gas.