As one of many smart products, the smart toilet is no exception. Compared with the ordinary toilet, the smart toilet brings us a more comfortable and convenient feeling, but after a long time of use, the smart toilet will inevitably appear some problems, not only the failure of the ordinary toilet, but also some intelligent problems.

The toilet, as one of the most frequently used household products at home, is quite inconvenient if it fails to use. Today, we will learn the common problems and maintenance methods of the intelligent toilet.

Smart toilet

1. Blockage: insufficient flushing or falling into foreign bodies or aging will cause toilet clogging. If it is soft clogging, simple dredging tools can be used to solve it. If it is hard clogging, it is generally necessary to disassemble the toilet to dredge.

2. Water leakage: the toilet tank fittings aging or damage failure, generally floating or water sealing cover problems, replacement can be.

3. Installation problems: Use glass glue or cement when installing the bottom of the toilet. Do not close the screw hole at the bottom of the toilet.

4. Button failure: the most common is double button, button failure can be replaced directly.

5. Water is not hot (other normal) : check the remote control, tank heating tube, water temperature sensor, hot fuse wire and computer board;

Solution: Is the temperature of the remote control set at normal temperature? Wait for 10 minutes, if there is no heat, please pull out the resistance value of the two ends of the measuring water tank heating wire is about 92 ohms, and then test whether there is 92 ohms or so resistance at both ends of the heating tube, if not, the fuse wire is broken, the resistance value at both ends of the temperature sensor (25K ~ 80K) is normal, if both are normal, the computer board is bad, such as changing the water tank, after changing the test is normal, If the water has been heated, the computer board should be changed together.

6. Seat temperature does not heat (other normal) : check the remote control, seat ring heating wire, temperature sensor, computer board and connect to **;

Solution: Use the remote control to set the heating state (wait 10 minutes for the seat). If there is no heating, please unplug the seat ring heating wire to measure the resistance values at both ends of 960+/-50 ohms. If there is no open heating wire, if there is a temperature sensor resistance values at both ends (5K ~ 15K), it is normal. If normal, the computer board is broken. If you change the seat ring, check whether it is normal after change. If the seat ring has been heated, the computer board should be changed together.

7. Wind temperature is not hot (other normal) : check the drying device and computer board;

Solution: Measure whether there is 89+/-4 ohm resistance at both ends of the drying electric heating wire frame. If there is no resistance, the drying device is broken. If there is, confirm the correct seat and then press the drying key to measure whether there is 220V voltage at both ends of the heating wire frame socket. Test the computer board carefully if changing the drying device. Note: If the short circuit between the motor slots sometimes leads to the opening of the electric heating wire frame due to the increase of the load and the slowing down of the speed, it will also lead to the scorching phenomenon of the computer board D882, then please replace the computer board and the drying device at the same time.