The shower is a kind of bathroom equipment for bathing, which is generally installed in our bathrooms. The use of the shower for a long time is very easy to appear a variety of problems, the most common problem is the water flow of the sleep shower becomes very small. When we use the shower, when the water becomes very small, we can choose to take the shower down, see if the shower outlet has garbage dirt, clean it up. Below, let’s take a look at the shower maintenance methods and common failures.
First, the pulse does not ignite after opening the water valve
Water heater failure cause analysis
l, the water pressure is too low;
2, the water filter is blocked, the shower head is blocked;
3, the battery positive and negative terminals installed reverse;
4, the battery voltage is too low or poor contact;
5, the inlet and outlet are reversed;
Water heater maintenance method
l, plus booster pump;
2, remove debris;
3. Reinstall the battery;
4, reinstall or replace the new battery;
5. Reinstall the inlet and outlet pipes;
Second, after opening the water valve pulse ignition but not fire
Water heater failure cause analysis
1, there is air in the trachea;
2, the battery voltage is insufficient;
3. The air source switch is not opened or the air intake filter is blocked
4, gas type does not match;
5. Valve seals rise after gas corrosion;
6. The output pressure of the cylinder reducing valve is too high or too low;
Water heater maintenance method
1, repeatedly switch the water valve to exhaust air until the fire;
2, replace the new battery;
3, open the air source switch or clear the blockage;
4, gas type does not match, prohibited use;
5, replace the valve seal;
6. Check and adjust the output pressure;
3. Deflagration sound occurs during ignition
Water heater failure cause analysis
l, cylinder pressure reducing valve pressure is too high;
2, the battery voltage is too low;
3, ignition needle carbon or dirt;
4. The location of the ignition needle is not correct or the distance from the burner is too far;
5, ignition for the burner hole, nozzle blockage;
Water heater maintenance method
1. Adjust the pressure of the cylinder pressure reducing valve;
2, replace the new battery;
3. Remove dirt;
4, adjust the ignition needle installation position;
5. Remove the debris blocked by the air outlet and nozzle;
Fourth, the water is not hot enough during use
Water heater failure cause analysis
1, the cylinder pressure reducing valve is damaged or the gas flow is not enough;
2, the air source switch has foreign bodies or semi-blocked;
3, gas main switch half open;
4, the intake nozzle, the gas pipe is too thin or the gas pipe is too long, resulting in insufficient air flow;
5, the gas does not match;
6, the water pressure is too high, the water pressure regulator system failure;
Water heater maintenance method
1, replace the qualified pressure reducing valve;
2. Remove foreign bodies;
3, open the main switch;
4, replace the air nozzle, gas pipe;
5, do not use;
6. Half close the inlet valve to reduce water pressure;
5. The fire is often turned off during use
Water heater failure cause analysis
1. Low water pressure and large water pressure fluctuation;
2, insufficient indoor air supplement;
3, insufficient battery voltage or poor contact;
4, the water yield is too little, the water temperature is too high, and the overheating device is protected;
Water heater maintenance method
l, the water twist to the appropriate position or small water position;
2, should be re-installed to ensure that the air supply is sufficient;
3, replace the new battery or reinstall;
4, the water twist to the appropriate position or water position;
6. The flame is yellow and has black smoke
Water heater failure cause analysis
1, the burner has dirt or its ejector pipe has dirt;
2, the cylinder gas is used up;
3, insufficient indoor air supplement;
4, gas type does not match;
5, high or low air pressure;
Water heater maintenance method
1. Remove dirt and carbon;
2, replace the cylinder with liquefied gas;
3, should be re-installed to ensure that the air supply is sufficient;
4, prohibit use;
5, adjust or replace the qualified pressure reducing valve
The above is the method of shower maintenance and common faults. A shower is a device that can adjust the flow of water and water itself, which can be used for bathing, washing hair and rinsing something that you want to wash. The shower is generally connected to the water heater, and most of the shower is integrated with the water heater. However, the current shower and water heater can also be separated, and the safety of separate use is relatively high. When we encounter problems, we should choose the right way to solve them, and don’t mess around.