What if the inner core of the floor drain cannot be removed

What if the inner core of the floor drain cannot be removed

2023-05-09 02:05:23

The inner core of the floor drain is essential in family life, and the bathroom without the floor drain drainage will be very inconvenient. So, the inner core of the floor drain can not be taken out how to do? This will need a certain way, it may be a long-term management of the floor drain, causing blockage, the following is full of hair, the specific operation can see the site to provide a detailed explanation ~

1. How to do if the inner core of the floor drain cannot be taken out
First, use a screwdriver to pry up the joint between the floor drain and the tile, or rotate the floor drain cover to the crawler gap, lift it and twist it open, and then use lubricant or loosening agent to loosen the components around the floor drain core until it is loosened. If none of the above methods work, use a cutting machine to remove the drain and replace it again. In addition, prolonged use can clog the floor drain, so it requires frequent inspection and maintenance, and some routine maintenance and cleaning is required.

2. What is the impact of removing the inner core of the floor drain
The floor drain should always be taken out to clean up, otherwise it is easy to cause blockage. Therefore, there is no harm in taking out the inner core of the floor drain, on the contrary, it is more conducive to drainage.

In fact, most floor drains can be removed from the plastic core by hand. You only need to remove the floor drain cover and filter in order to remove the floor drain core. Of course, if you can’t remove it by hand, use a screwdriver and pliers to remove the plastic core from the floor drain, but at the same time clean up the cement, sand and other debris around it.

3. Are the floor drains the same size
Floor drains are not all the same size.

The size of the bathroom floor drain is basically 10 * 10cm panel; The drain pipe is basically 50; If the drain pipe is modified, it must use a 40 drain pipe, which requires the purchase of ultra-thin drains. The size of the floor drain of washing machine, kitchen and bathroom is close to the specification of 10 * 10 or 11 * 11cm; There’s not much difference.

The height of the drain depends on the piping arrangement of the drainage system. Therefore, the height of the floor drain used with it is best within 200mm and 120mm, and must be discharged from the side.

There are two common methods of hidden installation: partial sinking cloths on bathroom floors and pad cloths used in bathrooms. To meet the requirements of toilet headroom and ergonomics, the former has a sinking space of 300mm and the latter has a seat height of 170mm.