What’s with the air conditioner spray? Common fault causes and solutions

What’s with the air conditioner spray? Common fault causes and solutions

2023-06-06 03:06:21

Winter is getting closer and closer, for many southern friends, summer artifact – air conditioning is rarely used. Although the air conditioner is good, but in the process of use there will always be some headaches, Xiaobian has encountered an air conditioning failure, that is, as soon as the air conditioner is turned on, the air conditioner will spray water out, sitting under the air conditioner is always sprayed into water droplets, I believe that many friends in life will also encounter such problems, Xiaobian will explain this problem and explain several common air conditioning problems in the following.

What’s with the air conditioner spray

The water spraying from the outlet of the indoor unit of the air conditioner may be caused by the deformation, falling off, or loosening of the water baffle, and the condensate dripping onto the wind wheel is thrown into the room by the wind wheel.

Solution: It can be treated by adjusting or changing the water baffle plate; On the other hand, if the cleaning and maintenance is not timely, the condensate will overflow from the auxiliary sink, drop on the wind wheel, and spray water from the outlet, which can be solved by adjusting the cleaning.

Common faults of air conditioning

1, the refrigeration effect is poor

Solution: In this case, the airflow sound is mainly caused by the poor circulation of refrigerant, and as long as the detailed inspection can know where the pipe is bent flat, this is mainly caused by the unprofessional installation in the bending pipe. In this case, you need to replace the connection pipe.

2. After shutdown, the indoor fan rotates slowly, and makes ear-piercing noise after startup

Solution: The speed of the indoor fan is controlled by the SCR, when the power supply voltage is low or the fluctuation is large, it will cause the SCR single-phase breakdown, the indoor fan still has voltage when the shutdown, the motor will still turn slowly, because the SCR is a single-phase breakdown, the motor power supply is non-sinusoidal waveform, the motor is not stable and the noise is large. The main control board needs to be replaced.

3, the heating effect of air conditioning is poor, and the wind speed is always low

Solution: When heating the air conditioner, due to the anti-cold air function, the indoor temperature sensor indoor heat exchanger reaches more than 25 degrees Celsius, the internal fan works with a breeze, and the temperature reaches more than 38 degrees Celsius to set the wind speed. If the air speed is low and the air outlet temperature is high, check whether the fan is normal. If the air speed is normal, the sensor may check the temperature incorrectly, causing the indoor fan to fail to operate at the set wind speed. Therefore, replace the sensor.

Every summer, people always say that air conditioning gives themselves a second life, no one is perfect, and air conditioning without any problems is almost impossible, some faults as long as the repair master to rectify, and can cool a whole summer. Through the above small series of air conditioning water spray failure and common air conditioning failures for everyone to do the relevant introduction, I hope that you can calmly face these failures in the future, waiting for the repair master to repair, if you have the ability to friends can also do it themselves.