What’s wrong with the air conditioner spraying water? Common fault causes and solutions

What’s wrong with the air conditioner spraying water? Common fault causes and solutions

2023-03-13 04:03:25

Winter is getting closer and closer, for many friends in the south, the summer artifact – air conditioning will rarely be used. Although the air conditioner is good, but in the use of the process will always be some headaches, I have encountered an air conditioning failure, is to open the air conditioner, the air conditioner will spray water outward, sitting under the air conditioner is always cold spray to water droplets, I believe that many friends in life will also encounter such a problem, I will explain the problem and explain a few common air conditioning failure problems below.

Air conditioner spraying water how

Water spraying from the air outlet of the indoor unit of the air conditioner may be caused by the deformation, falling off or loosening of the water barrier, and the condensate dropping onto the wind wheel and being thrown into the room by the wind wheel.

Solution: It can be dealt with by adjusting or replacing the water blocking plate; on the other hand, if the cleaning and maintenance are not timely, the condensate will overflow from the auxiliary water tank, drip on the wind wheel and spray water droplets from the air outlet, which can be solved by adjusting the cleaning.

Common faults of air conditioner

1、Poor cooling effect

Solution: The airflow sound like this is mainly caused by the poor circulation of refrigerant, which can be known only by detailed inspection where the tube is bent flat, which is mainly caused by the unprofessional installation in bending the tube. At this time, you need to replace the connection tube.

2、After shutting down the machine, the indoor fan slowly rotates and makes an ear-splitting noise after turning on the machine

Solution: split hanging indoor fan speed is controlled by the silicon controlled, when the power supply voltage is low or fluctuating, will cause the silicon controlled single-phase breakdown, shutdown indoor fan still has voltage, the motor will still slow rotation, due to the silicon controlled single-phase breakdown, motor power supply is not sinusoidal, motor operation is not smooth, noisy. Need to replace the main control board.

3, the air conditioning heating effect is poor, the wind speed is always very low

Solution: air conditioning heating, due to the anti-cold wind function, indoor temperature sensor indoor heat exchanger to 25 degrees Celsius or more when the fan to breeze work, the temperature reaches 38 degrees Celsius or more to set the wind speed work. The above failure first observed that the wind speed is low, and the air temperature is high, so check whether the fan is normal, when the wind speed is determined to be normal, the analysis may be incorrect sensor to check the temperature, resulting in indoor fan can not set the wind speed operation, so replace the sensor.

Every summer time, people always say that the air conditioner gives itself a second life, no one is perfect, and the air conditioner does not have any problems is almost impossible, some failures as long as the repair master to rectify, and can cool a whole summer. Through the above small part of the air conditioning water spray failure and air conditioning common failures and other aspects of the relevant introduction for everyone, I hope that we can face these failures in the future, waiting for the repair master repair, if you have the ability of friends can also do it yourself.