What is the reason for the air conditioner to switch on and off automatically?

What is the reason for the air conditioner to switch on and off automatically?

2023-03-09 06:03:15

Air conditioners, I’m sure no one is unfamiliar with it, are a very widely used device in our lives. The main function of air conditioners is to help us improve the indoor environment. Air conditioners bring us convenience but also bring us inconvenience. When we use the air conditioner for a long time after the air conditioner will appear a variety of problems. The automatic shutdown of the air conditioner is a very common one. The automatic shutdown of the air conditioner will directly affect our normal life. Here are some specific reasons and solutions.

1. Check whether the timer switch option on the air conditioner remote control is in the open state, if so, turn it to the closed state. Or see if the remote control is in sleep mode, it will automatically shut down when the temperature reaches the adjusted temperature, convert this mode to normal mode.

2. If the above methods have been tried, but still can not solve the problem, then check whether the manual switch is the problem, as follows: we recommend that you look at the air conditioning emergency switch (manual switch), (some on the inner panel, some need to open the inner panel to see), unplug the power, you key it back and forth with your hands, it may not reset caused by.

3. May also be due to poor contact between the pins and sockets of the air conditioning line, you can try to pull down the air conditioning switch, plug in other pins to try, to see if there will be automatic shutdown.

4. Automatic shutdown of the air conditioner may also be caused by the grid voltage: because the air conditioner are equipped with automatic protection against undervoltage, so when the grid voltage is unstable beyond the allowable range will automatically shut down. If the grid is often so, you can not use the air conditioner. Can only find the power supply department to solve. To install a voltage regulator is not realistic, can drive the price of air conditioning regulator is very high (to 5-10 kVA), in addition to the regulator itself also has its own adaptation range, the grid fluctuations are too large, it can not be adjusted, thus appearing in the case of automatic shutdown of the air conditioner.

5. Finally, when you can no longer solve this trouble, you should look for sales services, so that professional maintenance personnel to check the internal circuit of the air conditioner to see if a certain operating parameter is not normal, only the most targeted and authoritative on-site testing.

The reason why the air conditioner turns off automatically may be because we set the automatic shutdown or other modes, so that when the air conditioner turns off automatically, the first thing we have to do is to check the remote control settings to see if the air conditioner turns off because of the remote control. If so, we can correct it by making the appropriate settings. If it is not the settings that cause the air conditioner to shut down, then it may be a problem with the hardware of the air conditioner, and this time we need to repair the interior of the air conditioner.